Teaching is available in the undergraduate teaching labs during non-class hours.
| Technique |
Instrument |
# |
Capability |
Location |
| Infrared |
PE 1600 FTIR |
3 |
FT, diffuse reflectance accessory on one |
Dav. 126C |
| Infrared |
PE 283 B |
1 |
Dispersive, high resolution, transmission |
Hahn 006 |
| Infrared |
Midac M Series |
1 |
FT, Hig Res=0.5 cm-1, transmission |
Hahn 006 |
| UV-Vis |
PE Lambda 3A |
2 |
Scanning |
Dav. 126C |
| UV-Vis |
PE Lambda 4B |
1 |
Scanning |
Dav. 126C |
| UV-Vis |
PE Lambda 3 |
1 |
Scanning |
Dav. 126C |
| UV-Vis |
HP/Agilent 8453 |
1 |
Diode Array |
Dav. 123E |
| UV-Vis |
HP/Agilent 8453 |
1 |
Diode Array |
Dav. 128 |
| UV-Vis |
PE 330 |
1 |
Scanning w Integrating sphere |
Hahn 006 |
| Refractive Index |
Abbe 3L |
3 |
Liquid samples |
Dav. 126A |
| Refractive Index |
Abbe 3L |
2 |
Liquid samples |
Dav. 113 |
| Optical Rotation |
Rudolf Polarimeter |
1 |
Macro samples |
Dav. 126C |
| Optical Rotation |
Fisher Polarimeter |
1 |
Macro samples |
Dav. 126C |
| Luminescence |
PE LS 50 |
1 |
Fluorescence |
Dav. 123A |
| NMR |
JEOL Eclipse+500 |
1 |
Multinuclear, inverse, PFG,VT |
Hahn 006 |
| NMR |
Varian Inova 400 |
1 |
1H, 13C, 19F, 31P, VT, robot |
Hahn 006 |
| NMR |
Bruker MSL-300 |
1 |
Solids only, CP-MAS, Multinuclear, VT |
Hahn 006 |
| NMR |
Varian Unity-400 |
1 |
Multinuclear, inverse,VT |
Hahn 002 |
| MS |
Fisons Quattro |
1 |
triple quad: EI/CI, FAB, CID, MS-MS |
Hahn 006 |
| MS |
VG 7070E-HF |
1 |
High Resolution MS |
Engel 106 |
| GC -MS |
HP 5970 |
1 |
quad, EI only, max m/z = 550 |
Hanh 006 |
| ICP |
PE 6000 |
1 |
ICP scanning monochromator, most metals from 10 ppb to 500 ppm range.
Samples must be aqueous. |
Dav. 230 |
| AA |
Buck 200-A |
1 |
graphite furnance, can detect metals as low as 1 ppm in aqueous
solvents. |
Dav. 123A |
| AA |
PE 3110 |
2 |
flame AA/atomic emission, Lamps= Pb, Hg, Cd, Ni, S, Cr, Co, Cu,
Fe, Mn, Cu, Al, Mg, Si, Zn, Ti, K |
Dav. 123B |
| SFE |
Applied Sep. |
1 |
CO2, solid samples, 10ml extraction cell |
Dav. 123A |
| GC |
PE Autosystem |
4 |
HP5 megabore column, TCD & FID detector, Nelson 1022 integrator,
temp programable |
Dav. 123J |
| LC |
PE |
2 |
one isocratic series 200 LC pump, one gradient pump,785A programmable
absorbance detector, C-18 reverse phase column, GPC column |
Dav. 123A |
| GC |
Gow-mac |
3 |
packed columns, isothermal |
Dav. 126A |
| GC |
Gow-mac |
4 |
packed columns, isothermal |
Dav. 113 |
| Electrochemical Potentiostat |
EG&G 263A |
1 |
Cyclic Voltammetry |
Dav.123A |
| Polarography (dropping Mercury) |
EG&G 264A |
1 |
DC, normal pulse, differential pulse, stripping analysis |
Dav. 123A |
| Computing |
Gateway P5-200 |
7 |
Various applications, internet access, e-mail, CD-Rom, ZIP drives,
Windows 95, CAChe molecular modeling, SciFinder, Beilstein |
Dav. 123E |
| Computing |
Gateway 4DX-66 |
11 |
Various applications, internet access, e-mail, CD-Rom, ZIP drives,
Windows 95, CAChe molecular modeling, SciFinder, Beilstein |
Dav. 123E |
|